Test Chamber Preventative Maintenance
King Son Test Chamber Predictive Preventative Maintenance Program
King Son Customer Service provides Industry 4.0 – enabled Predictive Preventative Maintenance Programs to ensure the operation performance and product life of the testing chamber. The maintenance programs are tailored to meet your needs for all King Son - made test chambers.
King Son test chamber Predictive Preventative Maintenance Program includes
- Verification, validation of operation
- Check of electrical systems
- Check of humidity system
- Check of refrigeration system
- Check for refrigerant leaking
- Check of all gaskets and seals
- Repair the failed units
- Cleaning of filters
- Complete systems test
All test chamber maintenance is completed by the authorized King Son Distributor or third-party service agents.
King Son Environmental Test Chamber Preventative Maintenance Schedule
King Son Environmental Test Chamber Preventative Maintenance Schedule |
||||
---|---|---|---|---|
Chamber Sub system |
System subunit |
Maintenance, Inspection schedule |
||
On Electrical Systems |
High-Voltage Reading, Remote and/or Outside Unit |
Quarterly Maintenance |
|
|
|
High-Voltage Reading, Conditioning System |
Quarterly Maintenance |
|
|
|
Low-Voltage Reading, Control Side |
Quarterly Maintenance |
|
|
|
Compressor Amperage Reading |
Quarterly Maintenance |
|
|
|
Heat Amperage Reading |
Quarterly Maintenance |
|
|
|
Control Switch Test (Power, Heat, Cool, Light) |
Quarterly Maintenance |
|
|
|
Interior Lights Test |
Quarterly Maintenance |
|
|
On Humidity System |
Check the water demineralizer cartridge (monthly) |
Quarterly Maintenance |
|
|
|
Wash external water tank(s) (monthly) |
Quarterly Maintenance |
|
|
|
Purge the water from the test chamber |
Quarterly Maintenance |
|
|
|
Clean the steam generator(s) |
Quarterly Maintenance |
|
|
On Refrigeration System |
Condenser Coils Cleaning, Combing & Maintenance |
Quarterly Maintenance Quarterly Maintenance |
|
|
|
Static Pressures Check |
Quarterly Maintenance |
|
|
|
Operating Pressures Check |
Quarterly Maintenance |
|
|
|
Diagnostic Data Reading from Copeland Control Modules |
Quarterly Maintenance |
|
|
Control System & Performance |
High-Temperature Test: Rate to High Setpoint |
Quarterly Maintenance |
|
|
|
Low-Temperature Test: Rate to Low Setpoint |
Quarterly Maintenance |
|
|
On Electrical Systems |
Solenoid Covers & Coils |
|
Quarterly Inspections |
|
|
Condenser Fan Operation |
|
Quarterly Inspections |
|
On Humidity System |
Perform an in-house water test |
|
Quarterly Inspections |
|
|
Inspect hosing on water recirculation system |
|
Quarterly Inspections |
|
On Refrigeration System |
Site Glass Oil Level |
|
Quarterly Inspections |
|
|
Air Dryer Rust or Corrosion |
|
Quarterly Inspections |
|
|
Clearance Distance for Condenser |
|
Quarterly Inspections |
|
|
Air Handler Tightness Check to Prevent Air Leaks |
|
Quarterly Inspections |
|
|
Pipe Insulation |
|
Quarterly Inspections |
|
|
Condenser Pipe |
|
Quarterly Inspections |
|
Control System & Performance |
Rust or Corrosion |
|
Quarterly Inspections |
|
|
Water Leaks or Buildup of Condensation |
|
Quarterly Inspections |
|
|
Leaking Gaskets |
|
Quarterly Inspections |
|
|
Proper Clearance |
|
Quarterly Inspections |
|
Heaters (Wire & Tubular) |
|
|
|
Annual Maintenance |
Ground Wires |
|
|
|
Annual Maintenance |
Wires (Harnesses) |
|
|
|
Annual Maintenance |
Sensor Clips |
|
|
|
Annual Maintenance |
Verify Sensors and Controller Accuracy |
|
|
|
Annual Maintenance |